HCU Manual
HCU Manual
The HCU Manual is the basic version of a full range of control possibilities for Vexve hydraulic actuators. It is the right choice where simplicity is key and secure operation is needed at all times.
Model | Product no. |
Manual | 810000 |
Technical charasteristics
Control cabinet for 4 valves
- Dimensions 800 x 600 x 300 mm (W x H x D)
- Protection cIass IP65
Hand pump
- Double acting hand pump with pilot check valves
- Fluid viscosity: 10−500 mm2 /s
- Filtration: ISO code 16/13; SAE class 4 or better
- Fluid temperature: −20 °C − +80 °C
- Ambient temperature: −20 °C − +50 °C
- Max. pressure: 380 bar
- Pressure limiter: 200 bar (adjustable)
Oil tank
- Reservoir capacity: 5 l
Control valve block
- Control valves: 4 / 6 pcs.
- Max. pressure: 350 bar
- Positions of lever: 3 (Valve open – Neutral – Valve shut)
- It's possiböe to maneuver one valve at a time.
Pressure gauge
- Range: 0…315 bar
Indicator lamp panel
- Indicated open and shut positions of valves
- Low voltage powered
- Connected to position transmitter on actuator
Connection for portable pump unit
- Quick couplings with flat face casing
- Pump unit (sold separately) incl. transportation box, hydraulic hoses and electric cable
Technical documentation for the product
Brochures

Hydrox HCU Manual Datasheet EN