Vexve Control products

Vexve AM10

Compact single family house heating controller, outdoor temperature controlled, simple to install and operate.

Characteristics

  • Compact single-family house heating controller, simple to install and operate
  • Suitable for both radiator and Hydronic floor heating systems, easy installation without special tools
  • Delivery includes a control for a single heating circuit
  • All settings can be made and read directly from the controls on the front panel of the unit
  • Accessories can be easily connected with quick couplings; apartment units Automix 10 RB and RC
  • Stepless adjustment of the heating curve 1-9
  • Stepless parallel displacement (± 10 °C)
  • Stepless control of supply water minimum temperature (+15–35 °C) (floor heating mode)
  • Stepless control of supply water maximum temperature (+45–95 °C) (radiator heating mode)

Properties

  • All settings can be made and read directly from the controls on the front panel of the unit
  • 18 VAC supply voltage (low-voltage equipment, installation does not require an electrician)
  • The controller is integrated with the motor section (IP41)
  • 2 sensor inputs, RJ11/RJ12
  • 1 connection to a wired unit (under the device cover)
  • Motor unit 24VAC / 140s / 90 ° / 5Nm / 3-point control
  • Mechanical setting ensures that settings are maintained in the event of a power failure

Delivery contents:

Motor unit / AM10-controller 24 VAC / 140s / 90-degrees / 5Nm

  • IP41-protection class
  • Manual switch and mechanical position indication on the front panel

External power supply, 230 VAC 50 Hz / 18 VAC, 300 mA

  • 2,5-metre connection cable, DC plug connections directly to the motor part/controller

Supply water temperature sensor (KTY)

  • 1-meter connection cable, RJ12-connector
  • Pipe fastening ties

Outside temperature sensor (NTC 2K2)

  • 15-meter connection cable, RJ11-connector
  • Wall-mounted box

Connection adapters to valves

Vexve AM series and Termomix valves, as well as other standard four-point attachment valves (adapters available for several other valves).

This device meets the following environmental requirements and standards:

  • Operating temperature 0 … +40 °C
  • Storage temperature −20 … +60 °C
  • Shipping temperature −20 … +60 °C
  • Humidity 0–100 % RH, non-condensing conditions
  • RoHs 2002/95/EC
  • CE-mark 93/68/EEC
  • EMC-directive 2004/108/EEC
  • LVD- directive 2006/95/EC
  • General requirements for household control devices EN 60730–1:2000
  • Special requirements for temperature controllers EN 60730-2-9:2002